Back to FabImage Studio website
You are here: Start » Filter Reference » Hardware Support » Z4Sight » Z4Sight_Modbus_ReadCoils_Deprecated
Module: | ThirdParty |
---|
Reads the coil data table in local memory for data received from a Modbus controller.
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inDeviceID | Z4SightDeviceID* | Device identification number. | |
![]() |
inInstanceName | String* | Instance name of a given Industrial Communication protocol set in the MILConfig utility. | |
![]() |
inOffset | Integer | 0 - 65535 | Offset from which to start reading the data in the specified data table. |
![]() |
inCount | Integer | 1 - 2000 | Amount of the data to read. |
![]() |
outValues | BoolArray | Received values. |
Complexity Level
This filter is available on Advanced Complexity Level.
Disabled in Lite Edition