You are here: Start » Filter Reference » Hardware Support » Neousys » Neousys_SetDigitalOutput_Single
Module: | ThirdParty |
---|
Sets value to single digital output channel on a Neousys computer.
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inChannel | Integer | 0 - 15 | Desired output channel identifier |
![]() |
inValue | Bool | Value to set to desired output channel |
Remarks
I/O device driver software
This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it may be required to install WDT_DIO drivers and SDK.
WDT_DIO can be downloaded from the following website: https://www.neousys-tech.com/en/support-service/download-resources.
Add DLL path to system environment variable may be required.
Recommended WDT_DIO version for FabImage Studio usage is 2.3.1.
Availability
Before you use this filter make sure how many digital input and output channels does your Neousys device provide.
Compatibility
Neousys Watchdog Timer and Digital I/O support is not provided when using 32-bit FabImage on a 64-bit operating system. Please use 64-bit FabImage in such a case.
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
Filter Group
This filter is member of Neousys_SetDigitalOutput filter group.
See Also
- Neousys_SetDigitalOutput_Single_Checked – Sets value to single digital output channel on a Neousys computer. Additionally, does a read-back of the value to make sure it's identical to the written value.
- Neousys_GetDigitalInput_Single – Gets value of single digital input channel on a Neousys computer.