Sets strobe parameters.

Name Type Range Description
Input value inDeviceID String* Camera serial number, name or IP address, Auto = first camera
Input value inLineSelector HikvisionLine Strobe output line
Input value inLineSource HikvisionEvent Strobe source
Input value inLineInverter Bool* True if inverting output signal
Input value inStrobeEnabled Bool True if using strobe on selected line
Input value inStrobeDuration Integer* 0 - Duration of strobe pulse in microseconds
Input value inStrobeDelay Integer* 0 - Delay of strobe pulse in microseconds

Remarks

Camera driver software

This filter is intended to cooperate with a camera using its vendor SDK. To be able to connect to a camera, it is required to install Hikvision Machine Vision Software with camera dedicated drivers.

Hikvision Machine Vision Software can be downloaded from the following website: https://www.hikrobotics.com/en/machinevision/service/download?module=0 (registration may be required).

Add DLL path to system environment variable may be required.

Recommended Hikvision Machine Vision Software version for FabImage Studio usage is 4.0.1 (DLL version 4.0.0.5).

Camera identification

When there is only one camera connected to a computer, field inDeviceID can be set to Auto. In this case, first available camera will be found and connected.

inDeviceID field can be used to pick one of multiple cameras connected to computer. DeviceID can be set to:

  • Serial number - serial number of the device which can be viewed in the MVS software from Hikvision under Feature Tree / Device Control / Device Serial Number. Please note that this serial number may differ from the one printed on the device housing.
  • Camera name - user-defined ID which can be set in the MVS software from Hikvision under Feature Tree / Device Control / Device User ID.
  • IP address - ip address of the camera on the local network.
Setting bandwidth for GigEVision cameras

Bandwidth of Hikvision GigEVision cameras needs to be configured before use, otherwise packet loss and image artifacts may occur.

Open MVS software from Hikvision and connect to the camera. Open Settings / Options menu and go to Network tab. Bandwidth Control slider will be shown. To preserve new value of bandwidth after disconnecting power from the camera, you will need to save it using User Set Control parameters in Features tab.

Parallel execution

This filter cannot be placed in multiple Workers.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.