Back to FabImage Studio website

You are here: Start » Filter Reference » Hardware Support » Hikrobot » Hikrobot_GetLightParameters

Hikrobot_GetLightParameters


Module: ThirdParty

Get light parameters.

Name Type Range Description
Input value inDeviceID Integer* 1 - Device identification number - COM port number.
Input value inPortNumber HikrobotLightPortNumber Device light port number reference.
Output value outLightValue Integer Light brightness value [0-100].
Output value outLightState HikrobotLightState Light state after triggering.
Output value outTriggerEdge HikrobotEdgeType Trigger edge.
Output value outDurationTime Integer Duration time [ms].

Remarks

This filter allows to get the parameters of a specific light port of the device. The parameters are brightness value, state after triggering, trigger edge and duration time.

I/O device driver software

This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it is required to install Hikrobot VC4000 SDK.

Add DLL path to system environment variable is required.

In some computer models, digital inputs and outputs may operate in reverse logic (true is low signal level). Please check your device.

Recommended Hikrobot VC4000 SDK version for FabImage Studio usage is 1.2.0.

Device identification

inDeviceID field can be used to pick one of multiple I/Os connected to computer. DeviceID can be set to:

  • COM port number - the number of the COM port used to communicate with the I/O.

Complexity Level

This filter is available on Advanced Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.