Back to FabImage Studio website

You are here: Start » Filter Reference » Camera Support » Ensenso » Ensenso_LoadSettings_Deprecated

Ensenso_LoadSettings_Deprecated


Module: ThirdParty

Load parameters data from a file.

Name Type Description
Input value inDeviceID String* Device identifying number.
Input value inSettingsFile File JSON encoded parameters for camera.

Description

Loads Parameters node from settings file.

Remarks

Settings

To obtain settings from the camera:

  • From NxView Parameters window
    • Launch NxView
    • Open camera
    • Open Parameters window (menu Capture->Parameters...)
    • Adjust settings as wanted
    • Use Save... button
  • From NxTreeEdit application
    • Either:
      • Launch FabImage Studio, add Ensenso_GrabPoint3DGrid_Deprecated filter, Run it
      • Launch NxView, open camera
    • Launch NxTreeEdit, connect to wanted instance
    • Adjust settings as wanted, either in NxView or NxTreeEdit
    • right click on /Cameras/BySerialNo/WantedSerialNumber and select Copy value as JSON string
    • save to a simple text file using an editor

The settings include all camera parameters, including Link, Calibration and Parameters The saved file can be then used in inCalibrationFile and inSettingsFile arguments.

Camera identification

When there is only one Ensenso camera connected, the field inDeviceID can be set to Auto. In this situation, the first available camera will be used.

inDeviceID can be used to pick one of multiple cameras connected to the computer. inDeviceID should be set to camera ID.

Camera driver software

This filter is intended to cooperate with cameras using their vendor's SDK. In order to connect with the camera, it is required to install Ensenso SDK software, and uEye driver (same as in IDS camera filters)

Ensenso SDK and uEye driver can be downloaded from the following website: https://www.optonic.com/en/support/download/ensenso-sdk/

Recommended Ensenso SDK version for FabImage Studio usage is 3.5.1419 and uEye driver 4.96.1.

Parallel execution

This filter cannot be placed in multiple Workers.

Complexity Level

This filter is available on Basic Complexity Level.

Disabled in Lite Edition

This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.