Back to FabImage Studio website
You are here: Start » Filter Reference » Hardware Support » Z4Sight » Z4Sight_Modbus_WriteHoldingRegisters_float32
Module: | ThirdParty |
---|
Writes the holding register data table as 32-bit floating point numbers.
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inDeviceID | Z4SightSystemAndDeviceIdentifier* | Device identification. | |
![]() |
inInstanceName | String* | Instance name of a given Industrial Communication protocol set in the MILConfig utility. | |
![]() |
inOffset | Integer | 0 - 65534 | Offset to which to start writing the data in the specified data table. |
![]() |
inUseLittleEndian | Bool | Use little endian order for words in the registers. | |
![]() |
inValues | RealArray | Values to write. |
Complexity Level
This filter is available on Advanced Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.
Filter Group