Back to FabImage Library website

You are here: Start » Function Reference » Hardware Support » Z4Sight » Z4Sight_ConfigureDigitalOutput

Z4Sight_ConfigureDigitalOutput


Header: ThirdPartySdk.h
Namespace: fil
Module: ThirdParty

Configures digital output.

Syntax

void fil::Z4Sight_ConfigureDigitalOutput
(
	Z4Sight_State& ioState,
	ftl::Optional<const fil::Z4SightSystemAndDeviceIdentifier&> inDeviceID,
	int inOutput,
	ftl::Optional<bool> inInvert,
	ftl::Optional<const fil::Z4SightOutputSourceValue&> inOutputSource
)

Parameters

Name Type Range Default Description
Input will be modified ioState Z4Sight_State& Object used to maintain state of the function.
Input value inDeviceID Optional<const Z4SightSystemAndDeviceIdentifier&> NIL Device identification.
Input value inOutput int 0 - 63 Output signal.
Input value inInvert Optional<bool> NIL Sets whether the specified I/O signal should be inverted. This causes the low portion of the signal (the delay period) to be high and the high portion of the signal (the active portion) to be low.
Input value inOutputSource Optional<const Z4SightOutputSourceValue&> NIL Sets the type of signal to route to an output signal

Remarks

I/O device driver software

This filter is intended to cooperate with Zebra 4Sight devices, Zebra Indio I/O Cards and Zebra Concord Frame Grabbers using their vendor SDK. To be able to connect to the device, it is required to install Zebra AIL X SDK (Lite or Full version). Zebra 4Sight industrial PCs usually come with a preinstalled runtime license.

Add DLL path to system environment variable may be required.

Recommended Zebra AIL X SDK version for FabImage Studio usage is V22H1 (10.60.0776).

Device identification

Device field can be used to specify the number (rank) of the target board of the specified system type. Device can be set to:

  • DEFAULT - Specifies the default board. The default board is set in the MILConfig utility.
  • DEVn - Specifies the device number (rank) of the board (where 0 <= n <=15).

System field can be used to specify the system type. System can be set to:

  • HOST - Specifies the default build-in system like IO in industrial PC.
  • CONCORD - Specifies the IO system from Concord framegrabber.
  • INDIO - Specifies the IO system from Concord IO Card.
Note: It is strongly recommended to set the appropriate System parameter to avoid communication issues.