You are here: Start » Function Reference » Hardware Support » Z4Sight » Z4Sight_RegisterImpulse
Header: | ThirdPartySdk.h |
---|---|
Namespace: | fil |
Module: | ThirdParty |
Registers an impulse in a command list.
Syntax
void fil::Z4Sight_RegisterImpulse ( Z4Sight_State& ioState, ftl::Optional<const fil::Z4SightSystemAndDeviceIdentifier&> inDeviceID, int inCommandList, int inCommandBit, ftl::Optional<ftl::int64> inReferenceMoment, float inDelay )
Parameters
Name | Type | Range | Default | Description | |
---|---|---|---|---|---|
![]() |
ioState | Z4Sight_State& | Object used to maintain state of the function. | ||
![]() |
inDeviceID | Optional<const Z4SightSystemAndDeviceIdentifier&> | NIL | Device identification. | |
![]() |
inCommandList | int | 1 - 2 | I/O command list. | |
![]() |
inCommandBit | int | 0 - 7 | Bit of the command list. | |
![]() |
inReferenceMoment | Optional<int64> | NIL | Value of counter for which the command is to be registered (in seconds or counts). | |
![]() |
inDelay | float | 0.0 - ![]() |
0.0f | Delay from the specified counter value. |
Remarks
I/O device driver software
This filter is intended to cooperate with a Zebra 4Sight device using its vendor SDK. To be able to connect to the device, it is required to install Matrox MIL X SDK. Zebra 4Sight industrial PCs usually come with a preinstalled runtime license.
Add DLL path to system environment variable may be required.
Recommended Matrox MIL X SDK version for FabImage Studio usage is V22H1 (10.60.0776).
Device identification
Device field can be used to specify the number (rank) of the target board of the specified system type. Device can be set to:
- DEFAULT - Specifies the default board. The default board is set in the MILConfig utility.
- DEVn - Specifies the device number (rank) of the board (where 0 <= n <=15).
System field can be used to specify the system type. System can be set to:
- HOST - Specifies the default build-in system like IO in industrial PC.
- CONCORD - Specifies the IO system from Concord framegrabber.
This filter allows to register an impulse in one of the command lists. The specified command list must be configured using Z4Sight_ConfigureIOCommandList prior to using this filter.
See Also
- Z4Sight_ConfigureIOCommandList – Configures an I/O command list.
- Z4Sight_GetCounterReferenceValue – Gets the I/O command list's internal counter value at the current moment.
- Z4Sight_RegisterEdge – Registers an edge in a command list.
- Z4Sight_RegisterPulse – Registers a pulse in a command list.