Back to FabImage Library website

You are here: Start » Function Reference » Hardware Support » Neousys » Neousys_SetDigitalOutput_Single

Neousys_SetDigitalOutput_Single


Header: ThirdPartySdk.h
Namespace: fil
Module: ThirdParty

Sets value to single digital output channel on a Neousys computer.

Syntax

void fil::Neousys_SetDigitalOutput_Single
(
	Neousys_State& ioState,
	int inChannel,
	bool inValue
)

Parameters

Name Type Range Default Description
Input will be modified
ioState Neousys_State& Object used to maintain state of the function.
Input value
inChannel int 0 - 15 Desired output channel identifier
Input value
inValue bool Value to set to desired output channel

Remarks

I/O device driver software

This filter is intended to cooperate with a device using its vendor SDK. To be able to connect to a device, it may be required to install WDT_DIO drivers and SDK.

WDT_DIO can be downloaded from the following website: https://www.neousys-tech.com/en/support-service/download-resources.

Add DLL path to system environment variable may be required.

Recommended WDT_DIO version for FabImage Studio usage is 2.3.1.

Availability

Before you use this filter make sure how many digital input and output channels does your Neousys device provide.

Compatibility

Neousys Watchdog Timer and Digital I/O support is not provided when using 32-bit FabImage on a 64-bit operating system. Please use 64-bit FabImage in such a case.

See Also