Sets a digital output state of LEX computers.
Syntax
void fil::Lex_SetDigitalOutput ( Lex_SetDigitalOutputState& ioState, const int inOutput, bool inState )
Parameters
Name | Type | Default | Description | |
---|---|---|---|---|
![]() |
ioState | Lex_SetDigitalOutputState& | Object used to maintain state of the function. | |
![]() |
inOutput | const int | Number of output to change | |
![]() |
inState | bool | State of pin output to set |
Description
This filter can change state of digital outputs in LEX computers. Maximal number of output vary between different models.
Remarks
Running LEX related filters
Mechanism of Digital IO control of LEX computers demands to be run by Administrator account. LEX related filters will not work if FabImage Studio or any program based on FabImage Library is not run by Administrator. One can achieve that by right clicking on program to be ran and selecting "Run as administrator".
This filter is available only on 64-bit platform.
Multithreaded environment
This function is not guaranteed to be thread-safe. When used in multithreaded environment, it has to be manually synchronized.
Errors
List of possible exceptions:
Error type | Description |
---|---|
RuntimeError | Lex filters are available only on 64-bit platform. |
SystemError | Could not initialize F75111 DIO controller. LEX needs Administrator privileges to run. |
See Also