Back to FabImage Studio website
You are here: Start » Filter Reference » Modbus TCP » ModbusTCP_ReadMultipleIntegerRegisters
Function Code 03. Read the contents of a contiguous block of holding registers in a remote device
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inSocket | SocketId | Connected socket ID on port 502. | |
![]() |
inTimeout | Integer* | 10 - ![]() |
Timeout in milliseconds, block if not specified. |
![]() |
inUnitID | Integer | 0 - 255 | Default is 1. |
![]() |
inStartingAddress | Integer | 0 - 65535 | The address of the first holding register. |
![]() |
inCount | Integer | 1 - 125 | |
![]() |
inInputDataFormat | ModbusDataFormat | ||
![]() |
outIntegerValue | IntegerArray | Received integer value. |
Remarks
User manual
For more informations about using this filters please follow the link: Communication with Modbus TCP devices.
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.
Filter Group
This filters is member of ModbusTCP_Read filter group.