Back to FabImage Studio website
You are here: Start » Filter Reference » Modbus TCP » ModbusTCP_ReadInputRegisters_AsByteBuffer
Function Code 03. Read contiguous input registers in a remote device
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inSocket | SocketId | Connected socket ID on port 502. | |
![]() |
inTimeout | Integer* | 10 - ![]() |
Timeout in milliseconds, block if not specified. |
![]() |
inUnitID | Integer | 0 - 255 | Default is 1. |
![]() |
inStartingAddress | Integer | 0 - 65535 | The address of the first input register. |
![]() |
inCount | Integer | 1 - 125 | Number of registers to read. Each register is 2 Bytes in size |
![]() |
outData | ByteBuffer | Received register values. |
Remarks
User manual
For more informations about using this filters please follow the link: Communication with Modbus TCP devices.
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.
Filter Group
This filters is member of ModbusTCP_Read filter group.