Back to FabImage Studio website
You are here: Start » Filter Reference » Gocator » Gocator_StartAcquisition
Initializes and starts image acquisition in a Gocator device.
Name | Type | Range | Description | |
---|---|---|---|---|
![]() |
inAddress | GocatorAddress* | Gocator Device identifying IP address (e.g. "127.0.0.1") or serial number (e.g. "SN:17335") | |
![]() |
inInputQueueSize | Integer | 1 - 200 | Number of incoming frames that can be buffered before the application is able to process them |
Remarks
Device identification
When there is only one device connected, the field inAddress can be set to Auto. In this situation, the first available device will be used.
inAddress can be used to pick one of multiple devices connected to the computer. inAddress can be set to:
- IP Address - Gocator Device identifying IP address (e.g. "127.0.0.1")
- Serial Number - Gocator Device serial number with "SN:" prefix (e.g. "SN:17335")
Complexity Level
This filter is available on Basic Complexity Level.
Disabled in Lite Edition
This filter is disabled in Lite Edition. It is available only in full, FabImage Studio Professional version.